LSST Applications g0265f82a02+c6dfa2ddaf,g1162b98a3f+b2075782a9,g2079a07aa2+1b2e822518,g2bbee38e9b+c6dfa2ddaf,g337abbeb29+c6dfa2ddaf,g3ddfee87b4+a60788ef87,g50ff169b8f+2eb0e556e8,g52b1c1532d+90ebb246c7,g555ede804d+a60788ef87,g591dd9f2cf+ba8caea58f,g5ec818987f+864ee9cddb,g858d7b2824+9ee1ab4172,g876c692160+a40945ebb7,g8a8a8dda67+90ebb246c7,g8cdfe0ae6a+4fd9e222a8,g99cad8db69+5e309b7bc6,g9ddcbc5298+a1346535a5,ga1e77700b3+df8f93165b,ga8c6da7877+aa12a14d27,gae46bcf261+c6dfa2ddaf,gb0e22166c9+8634eb87fb,gb3f2274832+d0da15e3be,gba4ed39666+1ac82b564f,gbb8dafda3b+5dfd9c994b,gbeb006f7da+97157f9740,gc28159a63d+c6dfa2ddaf,gc86a011abf+9ee1ab4172,gcf0d15dbbd+a60788ef87,gdaeeff99f8+1cafcb7cd4,gdc0c513512+9ee1ab4172,ge79ae78c31+c6dfa2ddaf,geb67518f79+ba1859f325,geb961e4c1e+f9439d1e6f,gee10cc3b42+90ebb246c7,gf1cff7945b+9ee1ab4172,w.2024.12
LSST Data Management Base Package
Loading...
Searching...
No Matches
Protected Member Functions | List of all members
lsst.meas.algorithms.convertRefcatManager.ConvertGaiaXpManager Class Reference
Inheritance diagram for lsst.meas.algorithms.convertRefcatManager.ConvertGaiaXpManager:
lsst.meas.algorithms.convertRefcatManager.ConvertRefcatManager

Protected Member Functions

 _getFluxes (self, inputData)
 

Detailed Description

Special-case convert manager for Gaia XP spectrophotometry catalogs,
that have fluxes/flux errors, instead of magnitudes/mag errors.  The input
flux and error values are in units of  W/Hz/(m^2) (Gaia Collaboration, Montegriffo et al. 2022).
The the flux and fluxErr fields in the output catalog have units of nJy.

Definition at line 541 of file convertRefcatManager.py.

Member Function Documentation

◆ _getFluxes()

lsst.meas.algorithms.convertRefcatManager.ConvertGaiaXpManager._getFluxes ( self,
inputData )
protected
Compute the flux fields that will go into the output catalog.

Parameters
----------
inputData : `numpy.ndarray`
    The input data to compute fluxes for.

Returns
-------
fluxes : `dict` [`str`, `numpy.ndarray`]
    The values that will go into the flux and fluxErr fields in the
    output catalog.

Reimplemented from lsst.meas.algorithms.convertRefcatManager.ConvertRefcatManager.

Definition at line 548 of file convertRefcatManager.py.

548 def _getFluxes(self, inputData):
549 result = {}
550 for item in self.config.mag_column_list:
551
552 error_col_name = item.replace("_flux_", "_flux_error_")
553
554 result[item + "_flux"] = (
555 inputData[item] * u.Watt / u.Hz / u.meter / u.meter
556 ).to_value(u.nJy)
557 result[item + "_fluxErr"] = (
558 inputData[error_col_name] * u.Watt / u.Hz / u.meter / u.meter
559 ).to_value(u.nJy)
560
561 return result