LSST Applications g0da5cf3356+25b44625d0,g17e5ecfddb+50a5ac4092,g1c76d35bf8+585f0f68a2,g295839609d+8ef6456700,g2e2c1a68ba+cc1f6f037e,g38293774b4+62d12e78cb,g3b44f30a73+2891c76795,g48ccf36440+885b902d19,g4b2f1765b6+0c565e8f25,g5320a0a9f6+bd4bf1dc76,g56364267ca+403c24672b,g56b687f8c9+585f0f68a2,g5c4744a4d9+78cd207961,g5ffd174ac0+bd4bf1dc76,g6075d09f38+3075de592a,g667d525e37+cacede5508,g6f3e93b5a3+da81c812ee,g71f27ac40c+cacede5508,g7212e027e3+eb621d73aa,g774830318a+18d2b9fa6c,g7985c39107+62d12e78cb,g79ca90bc5c+fa2cc03294,g881bdbfe6c+cacede5508,g91fc1fa0cf+82a115f028,g961520b1fb+2534687f64,g96f01af41f+f2060f23b6,g9ca82378b8+cacede5508,g9d27549199+78cd207961,gb065e2a02a+ad48cbcda4,gb1df4690d6+585f0f68a2,gb35d6563ee+62d12e78cb,gbc3249ced9+bd4bf1dc76,gbec6a3398f+bd4bf1dc76,gd01420fc67+bd4bf1dc76,gd59336e7c4+c7bb92e648,gf46e8334de+81c9a61069,gfed783d017+bd4bf1dc76,v25.0.1.rc3
LSST Data Management Base Package
Loading...
Searching...
No Matches
Public Member Functions | Static Public Attributes | List of all members
lsst.meas.base.diaCalculationPlugins.Chi2DiaPsFlux Class Reference
Inheritance diagram for lsst.meas.base.diaCalculationPlugins.Chi2DiaPsFlux:
lsst.meas.base.diaCalculation.DiaObjectCalculationPlugin lsst.meas.base.catalogCalculation.CatalogCalculationPlugin lsst.meas.base.pluginsBase.BasePlugin

Public Member Functions

def getExecutionOrder (cls)
 
def calculate (self, diaObjects, diaSources, filterDiaSources, filterName, **kwargs)
 

Static Public Attributes

 ConfigClass = Chi2DiaPsFluxConfig
 
list inputCols = ["PSFluxMean"]
 
list outputCols = ["PSFluxChi2"]
 
string plugType = "multi"
 
bool needsFilter = True
 

Detailed Description

Compute chi2 of diaSource fluxes.

Definition at line 464 of file diaCalculationPlugins.py.

Member Function Documentation

◆ calculate()

def lsst.meas.base.diaCalculationPlugins.Chi2DiaPsFlux.calculate (   self,
  diaObjects,
  diaSources,
  filterDiaSources,
  filterName,
**  kwargs 
)
Compute the chi2 of the point source fluxes.

Parameters
----------
diaObject : `dict`
    Summary object to store values in.
diaSources : `pandas.DataFrame`
    DataFrame representing all diaSources associated with this
    diaObject.
filterDiaSources : `pandas.DataFrame`
    DataFrame representing diaSources associated with this
    diaObject that are observed in the band pass ``filterName``.
filterName : `str`
    Simple, string name of the filter for the flux being calculated.
**kwargs
    Any additional keyword arguments that may be passed to the plugin.

Reimplemented from lsst.meas.base.diaCalculation.DiaObjectCalculationPlugin.

Definition at line 482 of file diaCalculationPlugins.py.

487 **kwargs):
488 """Compute the chi2 of the point source fluxes.
489
490 Parameters
491 ----------
492 diaObject : `dict`
493 Summary object to store values in.
494 diaSources : `pandas.DataFrame`
495 DataFrame representing all diaSources associated with this
496 diaObject.
497 filterDiaSources : `pandas.DataFrame`
498 DataFrame representing diaSources associated with this
499 diaObject that are observed in the band pass ``filterName``.
500 filterName : `str`
501 Simple, string name of the filter for the flux being calculated.
502 **kwargs
503 Any additional keyword arguments that may be passed to the plugin.
504 """
505 meanName = "{}PSFluxMean".format(filterName)
506
507 def _chi2(df):
508 delta = (df["psFlux"]
509 - diaObjects.at[df.diaObjectId.iat[0], meanName])
510 return np.nansum((delta / df["psFluxErr"]) ** 2)
511
512 diaObjects.loc[:, "{}PSFluxChi2".format(filterName)] = \
513 filterDiaSources.apply(_chi2)
514
515

◆ getExecutionOrder()

def lsst.meas.base.diaCalculationPlugins.Chi2DiaPsFlux.getExecutionOrder (   cls)
Used to set the relative order of plugin execution.

    The values returned by `getExecutionOrder` are compared across all
    plugins, and smaller numbers run first.

    Notes
    -----
    `CatalogCalculationPlugin`\s must run with
    `BasePlugin.DEFAULT_CATALOGCALCULATION` or higher.

    All plugins must implement this method with an appropriate run level

Reimplemented from lsst.meas.base.catalogCalculation.CatalogCalculationPlugin.

Definition at line 478 of file diaCalculationPlugins.py.

478 def getExecutionOrder(cls):
479 return cls.FLUX_MOMENTS_CALCULATED
480

Member Data Documentation

◆ ConfigClass

lsst.meas.base.diaCalculationPlugins.Chi2DiaPsFlux.ConfigClass = Chi2DiaPsFluxConfig
static

Definition at line 468 of file diaCalculationPlugins.py.

◆ inputCols

list lsst.meas.base.diaCalculationPlugins.Chi2DiaPsFlux.inputCols = ["PSFluxMean"]
static

Definition at line 471 of file diaCalculationPlugins.py.

◆ needsFilter

bool lsst.meas.base.diaCalculationPlugins.Chi2DiaPsFlux.needsFilter = True
static

Definition at line 475 of file diaCalculationPlugins.py.

◆ outputCols

list lsst.meas.base.diaCalculationPlugins.Chi2DiaPsFlux.outputCols = ["PSFluxChi2"]
static

Definition at line 473 of file diaCalculationPlugins.py.

◆ plugType

string lsst.meas.base.diaCalculationPlugins.Chi2DiaPsFlux.plugType = "multi"
static

Definition at line 474 of file diaCalculationPlugins.py.


The documentation for this class was generated from the following file: