LSST Applications 27.0.0,g0265f82a02+469cd937ee,g02d81e74bb+21ad69e7e1,g1470d8bcf6+cbe83ee85a,g2079a07aa2+e67c6346a6,g212a7c68fe+04a9158687,g2305ad1205+94392ce272,g295015adf3+81dd352a9d,g2bbee38e9b+469cd937ee,g337abbeb29+469cd937ee,g3939d97d7f+72a9f7b576,g487adcacf7+71499e7cba,g50ff169b8f+5929b3527e,g52b1c1532d+a6fc98d2e7,g591dd9f2cf+df404f777f,g5a732f18d5+be83d3ecdb,g64a986408d+21ad69e7e1,g858d7b2824+21ad69e7e1,g8a8a8dda67+a6fc98d2e7,g99cad8db69+f62e5b0af5,g9ddcbc5298+d4bad12328,ga1e77700b3+9c366c4306,ga8c6da7877+71e4819109,gb0e22166c9+25ba2f69a1,gb6a65358fc+469cd937ee,gbb8dafda3b+69d3c0e320,gc07e1c2157+a98bf949bb,gc120e1dc64+615ec43309,gc28159a63d+469cd937ee,gcf0d15dbbd+72a9f7b576,gdaeeff99f8+a38ce5ea23,ge6526c86ff+3a7c1ac5f1,ge79ae78c31+469cd937ee,gee10cc3b42+a6fc98d2e7,gf1cff7945b+21ad69e7e1,gfbcc870c63+9a11dc8c8f
LSST Data Management Base Package
|
Classes | |
class | MergeMeasurementsConnections |
Variables | |
schema : `lsst.afw.table.Schema`, optional | |
initInputs : `dict`, optional | |
catalogs : `lsst.afw.table.SourceCatalog` | |
lsst.pipe.tasks.mergeMeasurements.catalogs : `lsst.afw.table.SourceCatalog` |
_DefaultName = "mergeCoaddMeasurements" ConfigClass = MergeMeasurementsConfig inputDataset = "meas" outputDataset = "ref" def __init__(self, schema=None, initInputs=None, **kwargs): super().__init__(**kwargs) if initInputs is not None: schema = initInputs['inputSchema'].schema if schema is None: raise ValueError("No input schema or initInputs['inputSchema'] provided.") inputSchema = schema self.schemaMapper = afwTable.SchemaMapper(inputSchema, True) self.schemaMapper.addMinimalSchema(inputSchema, True) self.instFluxKey = inputSchema.find(self.config.snName + "_instFlux").getKey() self.instFluxErrKey = inputSchema.find(self.config.snName + "_instFluxErr").getKey() self.fluxFlagKey = inputSchema.find(self.config.snName + "_flag").getKey() self.flagKeys = {} for band in self.config.priorityList: outputKey = self.schemaMapper.editOutputSchema().addField( "merge_measurement_%s" % band, type="Flag", doc="Flag field set if the measurements here are from the %s filter" % band ) peakKey = inputSchema.find("merge_peak_%s" % band).key footprintKey = inputSchema.find("merge_footprint_%s" % band).key self.flagKeys[band] = pipeBase.Struct(peak=peakKey, footprint=footprintKey, output=outputKey) self.schema = self.schemaMapper.getOutputSchema() self.pseudoFilterKeys = [] for filt in self.config.pseudoFilterList: try: self.pseudoFilterKeys.append(self.schema.find("merge_peak_%s" % filt).getKey()) except Exception as e: self.log.warning("merge_peak is not set for pseudo-filter %s: %s", filt, e) self.badFlags = {} for flag in self.config.flags: try: self.badFlags[flag] = self.schema.find(flag).getKey() except KeyError as exc: self.log.warning("Can't find flag %s in schema: %s", flag, exc) self.outputSchema = afwTable.SourceCatalog(self.schema) def runQuantum(self, butlerQC, inputRefs, outputRefs): inputs = butlerQC.get(inputRefs) dataIds = (ref.dataId for ref in inputRefs.catalogs) catalogDict = {dataId['band']: cat for dataId, cat in zip(dataIds, inputs['catalogs'])} inputs['catalogs'] = catalogDict outputs = self.run(**inputs) butlerQC.put(outputs, outputRefs) def run(self, catalogs):
Definition at line 201 of file mergeMeasurements.py.
lsst.pipe.tasks.mergeMeasurements.initInputs : `dict`, optional |
Definition at line 131 of file mergeMeasurements.py.
lsst.pipe.tasks.mergeMeasurements.schema : `lsst.afw.table.Schema`, optional |
pseudoFilterList = pexConfig.ListField( dtype=str, default=["sky"], doc="Names of filters which may have no associated detection\n" "(N.b. should include MergeDetectionsConfig.skyFilterName)" ) snName = pexConfig.Field( dtype=str, default="base_PsfFlux", doc="Name of flux measurement for calculating the S/N when choosing the reference band." ) minSN = pexConfig.Field( dtype=float, default=10., doc="If the S/N from the priority band is below this value (and the S/N " "is larger than minSNDiff compared to the priority band), use the band with " "the largest S/N as the reference band." ) minSNDiff = pexConfig.Field( dtype=float, default=3., doc="If the difference in S/N between another band and the priority band is larger " "than this value (and the S/N in the priority band is less than minSN) " "use the band with the largest S/N as the reference band" ) flags = pexConfig.ListField( dtype=str, doc="Require that these flags, if available, are not set", default=["base_PixelFlags_flag_interpolatedCenter", "base_PsfFlux_flag", "ext_photometryKron_KronFlux_flag", "modelfit_CModel_flag", ] ) priorityList = pexConfig.ListField( dtype=str, default=[], doc="Priority-ordered list of filter bands for the merge." ) coaddName = pexConfig.Field( dtype=str, default="deep", doc="Name of coadd" ) def validate(self): super().validate() if len(self.priorityList) == 0: raise RuntimeError("No priority list provided") class MergeMeasurementsTask(pipeBase.PipelineTask):
Definition at line 129 of file mergeMeasurements.py.